Symmons Shower Cartridge Replacement: Temptrol, Safetymix and Showeroff

How to get a Symmons shower spindle out, tell the Temptrol TA-10 from the Safetymix C-5, and match the Showeroff PS-1 and NS-1 to the valve.

Updated

On this page

Short answer. Symmons lists each spindle for one valve line. A Temptrol valve takes the TA-10 flow control spindle. A Safetymix valve takes the C-5. Showeroff metering shower valves take the NS-1 if the valve is from 1983 to date and the PS-1 if it is from 1960 to 1983. The TA-10 and C-5 look close in photos, since both are brass with a perforated barrel, so identify the valve before you trust the spindle.

Jump to the valve and part table or where to get it.

Get to the cartridge

These are Symmons’ own Temptrol steps, from its TA-10 replacement guide and its 262BODY, 262XBODY and 261XBODY install guide.

  1. Shut off the water to the valve.
  2. Open the valve to hot before anything comes apart. Symmons’ replacement guide says to turn the handle counter-clockwise until it stops. Symmons’ website FAQ says about half a turn. The guide is more specific.
  3. Take off the trim. Remove the plug button, the handle screw and the handle. Remove the two escutcheon screws, then the dial and the escutcheon. Unscrew the dome cover counter-clockwise.
  4. Stop and look before you pull the cap. The cap and the spindle come out together, so decide now which valve line you are in, using the table and the checks below.

A Safetymix is trimmed differently. Symmons’ instructions have you loosen the set screw, then take off the lever handle, the dome cover and the escutcheon in that order. Its parts list shows no dial. Open it to about the warm position, then unscrew the cap and leave the packing nut in place so it does not distort.

What it is: Symmons shower valve spindles and cartridges

Here is how Symmons lists each part on its own site, as of October 30, 2026.

PartSymmons lists it forStatus
TA-10Temptrol shower series valvesCurrent
TA-10-RPTemptrol shower series valves, the TA-10 in retail packagingCurrent
TA-10-3HLTemptrol shower series valves, low flowCurrent
TA-10-NYCTemptrol shower series valves, maxi flowRetired
TA-10-NO/CHTemptrol shower series valves, non-chatterRetired, TA-10-3HL recommended
C-5Safetymix valvesCurrent
NS-1Showeroff series valves from 1983 to dateCurrent
PS-1Showeroff series valves from 1960 to 1983, with an adaptor plateCurrent

Temptrol. Symmons describes it as a solid brass, bronze and stainless steel valve with an adjustable piston. The trims Symmons’ steps cover have a dial behind the handle. Its install guide covers the bodies 262BODY, 262XBODY and 261XBODY and names the TA-10 as the flow control spindle in each. Symmons’ 2019 item number chart renumbered the older 46 series to the 26 series, so a body numbered 46-2-BODY is the older name for what is now the 262BODY.

Safetymix. Symmons calls it its original pressure-balancing valve. The C-5 is listed as the flow control spindle.

Showeroff. Symmons describes it as a piston-actuated metering shower valve. The PS-1 and NS-1 are both current, so the NS-1 does not replace the PS-1. If you cannot date the valve, or yours is none of these, send a photo.

Pull it the right way

Confirm it once it is out

Where to get the replacement

These are the Symmons replacements we stock, each listed with the Symmons number it replaces. A card for a part we do not stock yet sends you to the photo form. They are aftermarket parts, not made by or affiliated with Symmons. Card lengths are listing figures, and length alone never settles a match.

Temptrol valves

Safetymix valves

Showeroff valves

Still not sure which one you have?

The tells above settle the common cases. For a spindle worn past its stamp, a valve with no readable marking or an unknown Showeroff date, photograph it at the fixture and send us the photo. A specialist confirms the exact replacement and posts an itemized written quote. Nothing is charged until you approve it.

Putting the new one in

On a Temptrol, Symmons’ steps run in reverse. Thread the new TA-10 into the cap assembly clockwise, all the way, so the spindle is drawn close to the cap. Put the cap and spindle back in the valve and tighten the cap clockwise with a wrench. Symmons warns that screwing the cap in before the spindle is drawn close will damage the cap and spindle. Close the valve with the handle, restore the water and check for leaks. Symmons gives the same drawn-close instruction for a Safetymix.

Both supplies must be on, because Symmons says the valve will not pass water otherwise. If the valve gives hot water when first opened and turns colder toward hot, Symmons says the hot supply is piped to the cold inlet. Where the piping is not accessible, its fix is the T-108 reverse seat kit with tool, and older installations may also need the TA-4 seat kit.

The temperature limit stop is a scald control. Symmons’ install guide sets it after installation, by the installer, to state and local code. Put the handle on the spindle, open the valve to the maximum temperature you want and turn the limit stop screw clockwise until it seats. Symmons warns that failing to set it properly may result in serious scalding. After any service, run the valve to full hot and confirm it still matches what the code and the job require.

Common questions

What shower cartridge does a Symmons Temptrol valve take?

Symmons lists the TA-10 flow control spindle for Temptrol shower series valves. It is a brass spindle whose perforated barrel houses the pressure balancing piston, and it comes out together with the cap assembly. Symmons also lists a low flow version, the TA-10-3HL.

Is the Symmons TA-10 the same as the C-5?

No. Symmons lists the TA-10 for Temptrol valves and the C-5 for Safetymix valves, each with its own washer kit. They look close in photos, since both are brass with a perforated barrel, a stainless ring and a splined tip. In Symmons' catalog photos the TA-10 has SYMMONS stamped on the shaft and a short thread under the flange, while the C-5 has a much longer thread. Match the spindle to the valve it came out of.

What do TA-10-3HL, TA-10-NYC and TA-10-NO/CH mean?

All three are Temptrol spindles. Symmons lists the TA-10-3HL as low flow and the TA-10-NYC as maxi flow, which allows a higher flow. As of October 30, 2026 Symmons shows the TA-10-NYC as retired with no replacement named, and the non-chatter TA-10-NO/CH as retired with the TA-10-3HL as its recommended replacement.

Which cartridge does a Symmons Showeroff valve take, PS-1 or NS-1?

Symmons lists the PS-1 for Showeroff series valves from 1960 to 1983, supplied with an adaptor plate, and the NS-1 for Showeroff series valves from 1983 to date. Both are current Symmons products, so the NS-1 does not replace the PS-1. If you cannot date the valve, send a photo of the valve and the cartridge.

Why does my Symmons Temptrol only give all hot or all cold water?

Symmons says this points to the pressure balancing piston inside the TA-10 spindle jamming on debris such as minerals, dirt or solder. With the water off and the spindle out, shake it and listen for the piston clicking. If it sticks, tap the handle end against a solid object and soak the spindle in household white vinegar. If that fails, replace the spindle.

Sources